HydroMassage • JTL Enterprises, Inc.
15395 Roosevelt Blvd • Clearwater, FL 33760 USA • 1-727-536-5566 • Fax 1-727-536-6633
HydroMassage Electrical Requirements – 50Hz, Europe & Other Countries
Technical Specifications
Electrical Requirements
Series 300-400 Models *these items are required for EACH HydroMassage unit
• A: 230 Volt, single-phase, dedicated line with a 16 Amp dedicated slow blow
Type C or K breaker and 2,5mm
2
wire (1 hot, 1 neutral, 1 ground*). Install 15cm
above the floor. on diagram. Install an RCD or GFIC if required by local code
• B: CAT-5 or CAT-6 terminated network jack (able to connect to front desk PC). on diagram
• B: For use with external timer ONLY (ex. key fob-reader), 230 Volt, 13 Amp outlet required.
Install 15cm above floor. on diagram.
• D: For use with External Cooling System ONLY. 230 Volt, 13 A outlet. Pulls 6 Amps. Install
15cm above floor. on diagram (350, 450X models only).
Electrical Wiring Diagrams
Unique set of items A, B, C required FOR EACH HydroMassage unit. If necessary, location of outlets
above may be moved within +/- 13cm. Call +1-727-536-5566 for details.
Water Requirements Distilled water required. Distilled water is available major supermarkets or
directly from a water supplier (water delivery service).