920-115-000-00-1-A 1/2
OPERATING MODES
MEMORY
BACK-UP
In the event of a power failure, an internal circuit will maintain the
programming and time. However, the time will have to be re-set if the
power failure exceeds 6 hours.
PROGRAM THE TIME AND DAY
PROGRAM COMFORT, ECONOMY AND VACATION SETTINGS
The Comfort , Economy and Vacation settings respectively
represent the temperatures that you wish to have during the day ( ),
at night or while you are away at work ( ), or while you are away for
an extended period ( ).
PROGRAMMING
1 Set the time using the Hour and Min buttons.
2 Set the day using the Day button.
MANUAL
AUTO
Allows you to manually adjust the temperature setpoint.
1 To activate this mode, press on Mode / Return to
display the icon.
2 Set the desired temperature using the buttons
or select the pre-programmed , or settings.
Executes the default schedule or your own programming.
Use this mode to maximize energy savings. T
o activate it,
press on Mode / Return to display the icon. The or
icon indicates which temperature setting is used. Also,
the icon of the program number will be shown. (i.e. )
HOMEOWNER’S GUIDE
FOR MODEL NTG5110 (120 VAC)
T
o modify the Saturday and Sunday schedules:
When making modifications, make sure you are in the right program.
For example, if you are modifying the temperature for the time you
wake up, make sure you are in .
1
Press on Day button until SA or SU is displayed.
2 Press on PGM button to select and Hour and Min buttons
to enter the time you wake up on weekends.
3 Press on PGM button to select and then Hour and Min
buttons to enter the time you go to sleep on weekends.
4
Press on Mode / Return button to exit this function.
Schedule/Day
MON.
6 AM
9 AM
5 PM
11 PM
TUES.
6 AM
9 AM
5 PM
11 PM
WED.
6 AM
9 AM
5 PM
11 PM
THU.
6 AM
9 AM
5 PM
11 PM
FRI.
6 AM
9 AM
5 PM
11 PM
SAT.
7 AM
---
---
11 PM
SUN.
7 AM
---
---
11 PM
88 °F
74 °F
88 °F
74 °F
1 Press PGM to access the programming mode.
2 Press Day to select the day to be programmed (hold for 3 seconds
to select all days of the week).
3 Press PGM to select program number (1, 2, 3 or 4).
A- Press Hour and Min to program the time.
OR
B- Press Clear to clear a time entry.
4 Repeat step 3 for remaining programs.
5 When you have completed your programming, press Mode / Return
to exit the programming mode.
Note: It is faster to program the same schedule for the entire week; then
modify the exception days (i.e. Saturday and Sunday).
EXAMPLE
This example applies to people who are home throughout the week.
Comfort period from 6:00 AM to 11:00 PM (Prog. 1)
Economy period from 11:00 PM to 6:00 AM (Prog. 2)
Identical schedule for all days of the week.
1 Press PGM to access the programming mode.
2 Press and hold Day for 3 seconds to select every day of the
week.
3 Press PGM to select Program 1.
4 Press Hour to enter 6:00 AM .
5 Press PGM to select Program 4.
6 Press Hour to enter 11:00 PM .
Note: You may need to clear time entries for Programs 2 and 3. To do so,
press PGM, select Program 2 and press Clear. Press PGM, select
Program 3 and press Clear.
7 When you have completed your programming, press Mode / Return
to exit the programming mode.
First, program your schedule. You can program 4 different settings for
each day of the week. For each day, enter:
Time you wake up (Prog.1)
Time you leave for work (Prog.2)
Time you return home (Prog.3)
Time you go to bed (Prog.4)
DEFAULT SCHEDULE
This thermostat is pre-programmed with the following default schedule.
It applies to people who wake up at 6:00 AM, leave for work by 9:00 AM,
return home for 5:00 PM and go to sleep for 11:00 PM.
PROGRAM YOUR SCHEDULE OR
MODIFY THE DEFAULT SCHEDULE
If the pre-programmed schedule fits your lifestyle, skip the following
section.
1 To program the Comfort temperature, select the desired tempera-
ture using the buttons and hold the button until the
icon is diplayed (app. 3 seconds).
2 To program the Economy temperature, select the desired tempera-
ture using the buttons and hold the button until the
icon is displayed (app. 3 seconds).
3 To program the Vacation temperature, select the desired tempera-
ture using the buttons and hold on the and buttons
simultaneously until the icon is displayed (app. 3 seconds).
4 Press the Mode / Return button to exit this function and return to the
normal operating mode.
As an ENERGY STAR
R
partner,
Nuheat has determined that this thermostat
meets the Energy St
ar guidelines for energy efficiency.
TM
This thermostat is pre-programmed with default Comfort (88°F),
Economy (74°F) and Vacation (74°F) setpoints. If the default
temperature settings suit your personal preferences, skip the following
section.
MODIFY THE DEFAULT TEMPERA
TURE SETTINGS
TEMPORARY OR PERMANENT TEMPERATURE BYPASS
This operation allows you to temporarily modify the floor temperature
while you are in the Automatic mode. Simply press on or but-
tons to select the desired temperature, or the or button to select
the Comfort or Econo settings you have programmed. This tempera-
ture will be maintained until the beginning of the next programmed
schedule.
You can also switch to the Vacation setting for a prolonged absence
by pressing on the button. In that case, the temperature bypass is
permanent. To return to the normal operating mode, press on Mode /
Return button.
If you wish to immediately return to the programmed settings, press on
Mode / Return button twice.
TECHNICAL SPECIFICATIONS
• Model: NTG5110 (120 VAC)
• Display range: 32°F to 140°F (0°C to 60°C)
• Setting range: 40°F to 104°F (5°C to 40°C)
• Comfort default setting: 88°F (31°C)
• Economy default setting: 74°F (23°C)
• Vacation default setting: 50°F (10°C)
14/05/03 920-115-000-00-1-A 2/2
EARLY START FUNCTION
This thermostat is equipped with a function that enables it to calculate
the optimum time to start the heating system to achieve the desired
temperature setting by the programmed time. It could start the heating
system as early as 6 hours prior if necessary.
Every day, the thermostat will automatically re-evaluate how early to
start heating, based on the previous day’s performance.
The switch on the back of the thermostat is factory-set to Early Start
ON. To turn it off, see SWITCH SELECTION.
WARRANTY
NUHEAT INDUSTRIES ONE (1) YEAR LIMITED WARRANTY
This product is guaranteed against workmanship defects for a one-year
period following the initial date of purchase. During this period,
NUHEAT will repair or replace, at our option and without charge, any
defective product which has been used under normal conditions.
The warranty does not cover delivery costs and does not apply
to product
s poorly installed or randomly damaged following installation.
This warranty cancels and replaces any other manufacturer's express
or implied warranty as well as any other company commitment.
NUHEAT cannot be held liable for related or random damages
following the installation of this product.
The defective product as well as the purchase invoice must be returned
to the place of purchase or mailed, prepaid and insured, to the
following address:
NUHEAT INDUSTRIES LTD.
USA CANADA
880 Grant Avenue 1689 Cliveden Avenue
Blaine, WA Delta, BC
98230 V3M 6V5
1 (800) 778-9276
www.nuheat.com
NUHEAT is a registered trademark of Nuheat Industries LTD.
TM
SWITCH SELECTION
Function
UP DN
SW1
SW2
SW3
SW5
Temperature format °F
Disable
Enable
12 h
24 h
Enable
Disable
°C
Early Start
Time format
Permanent backlight
This thermostat is factory-set to the following values.
Factory pre-sets
SPECIAL FEATURES
To change these pre-sets:
1 Locate the screw at bottom of thermostat. Unscrew.
2 Remove thermost
at faceplate.
3 Locate the switches at the back of the faceplate. Set the switches
to your preferences.
4 Put the faceplate back on the thermost
at.
5 Secure the thermostat with the screw.
1
2
3
4
5
GFCI TEST
We recommend you test the GFCI monthly. If the test is not success-
ful, cut power to the heating system and call customer service, or return
the thermostat to your supplier for verification.
1 Adjust the setpoint temperature until the heating indicator
( ) appears on-screen.
2 Press TEST. The test is successful if the GFCI warning light is ON
and power is cut-off.
3 Switch power to Standby, then reset to ON.
Warning light: If this comes on during normal operation, cut power to
the heating system and have an electrician verify the inst
allation.
ELECTRICIAN’S INSTRUCTIONS
FOR MODEL NG110 (120 VAC)
INSTALLATION
This power base is designed to control electric floor-warming systems.
The resistive load must not exceed 1800 watts (NI) @ 120 VAC (15 A).
The thermostat is equipped with a Ground Fault Circuit Interrupter
(GFCI) and therefore the isolation of the line and load are required for
operation. Do not cap all the white wires together. During a ground
fault, both line and load will be cut-off. Connect thermostat as shown on
diagram.
Must be installed in accordance with national and local electrical
codes.
TURN OFF POWER TO THE HEATING SYSTEM AT THE MAIN
POWER PANEL TO AVOID ELECTRICAL SHOCK.
1 Connecting wires and mounting power base
Connect the power base
wires to the supply and load
using solderless connectors
for copper wires.
See diagram.
• Push the excess wire back
into the electrical box to
prevent interference with the
power base.
NOTE: All cables and connections must conform to the local
electrical code.
WARNING: Special CO/ALR solderless connectors must be used
when connecting with aluminum conductors.
2 Connecting temperature sensor wire
• The wire must pass outside
the electrical box and follow
the wall down to the floor.
The sensing probe should be
placed in a representative
heat area for maximum
system performance.
The sensing probe should
be centered between the
wires in the mat. The
temperature sensor wire
cannot cross any heater
wires and the sensing probe
must NOT be directly on or
adjacent to a heating wire.
• Secure the power base with the screw.
• Connect the temperature sensor wire to terminals 3 and 4 on the
power base (no polarity needs to be respected).
• Once the power base is properly installed, mount the faceplate.
14/05/03 920-112-000-00-1-A
NG110
SUPPLY
LOAD
WARRANTY
NUHEAT INDUSTRIES ONE (1) YEAR LIMITED WARRANTY
This product is guaranteed against workmanship defects for a one-year
period following the initial date of purchase. During this period,
NUHEAT will repair or replace, at our option and without charge, any
defective product which has been used under normal conditions.
The warranty does not cover delivery costs and does not apply
to products poorly installed or randomly damaged following installation.
This warranty cancels and replaces any other manufacturer's express
or implied warranty as well as any other company commitment.
NUHEAT cannot be held liable for related or random damages
following the installation of this product.
The defective product as well as the purchase invoice must be returned
to the place of purchase or mailed, prepaid and insured, to the
following address:
NUHEAT INDUSTRIES LTD.
USA CANADA
880 Grant Avenue 1689 Cliveden Avenue
Blaine, WA Delta, BC
98230 V3M 6V5
1 (800) 778-9276
www.nuheat.com
TECHNICAL SPECIFICATIONS
Model: NG110
Supply: 120 VAC, 50/60 Hz
Load: 15 A maximum
Power: 1800 watts (NI) @ 120 VAC
Ground Fault Circuit Interrupter (GFCI): Class A (5 mA)
Approvals: CSA / C,US
Storage: -4°F to 120°F (-20°C to 50°C)
NUHEAT is a registered trademark of Nuheat Industries LTD.
TM
Keep the thermostat’
s air vents clean and free from
obstructions.
1 Locate the screw at the
bottom of the front module.
2 Secure the thermostat
with the screw.
3 Turn the power back on.
MOUNTING THE FACEPLATE
POWER ON
When the unit is power on for the first time,
the following appears on-screen:
Time (0:00)
Floor temperature
Manual mode icon ( )
If improperly installed, you will see the LO
or HI error message.
LO: Floor temperature is below C
(32°F); or temperature probe is
defective (open) or not connected.
*If the heating indicator is also
displayed, then the relay is closed
and current is going through the load.
HI:
NT5
1-800-778-WARM
www.nuheat.com
Day
Test
Stand By
On
Hour
Min
Pgm
Clear
Mode/Ret
R
Floor temperature is above 60°C (140°F);
or temperature probe is shorted.
GFCI TEST
NT5
1-800-778-WARM
www.nuheat.com
Day
Test
Test
Stand By
On
Hour
Min
Pgm
Clear
Mode/Ret
R
1 Adjust the setpoint temperature until the heating indicator ( )
appears on-screen.
2 Press TEST. The test is successful if the GFCI warning light is ON
and power is cut-off. The heating indicator ( ) should still appear.
3 Switch power to Standby, then reset to ON.
If test fails:
A- Verify installation.
B- Check the load wires.
C- Verify that the thermostat is in
heating mode with Heating
indicator ON.
Once you’ve identified the
problem, run the GFCI test again.